How cycling performance is measured and interpreted. This module follows the extracted material on laboratory protocols, ergometry, the critical-power model, submaximal and maximal testing, gas-volume corrections, variability and reliability.
Each abbreviation is written in full the first time it appears in a section; later uses carry the full term as a hover or tap hint. Expansions follow this module's source material.
Choose a level. Each one asks more of you: L1 terms, L2 mechanisms, L3 application, L4 quantitative work and assumptions, MPT appraisal. All levels use this module's extracted material; numbers and claims carry their source.
At this level you should: Know when testing must not start or must stop. (Foundation)
Screen before maximal testing (extracted 16.1) and stop on the listed clinical indications (karim khan p. 155–156; 16.10).
At this level you should: Explain ramp and step protocols and the plateau criterion. (Understanding)
Ramp protocols increase power continuously at 20–30 W/min; step protocols hold stages [4, pp. 289–291]. A oxygen uptake (V̇O₂) plateau is the primary maximal oxygen uptake (V̇O₂max) criterion (16.4).
At this level you should: Apply the critical-power model to an effort. (Application)
The hyperbolic two-parameter model: tlim = work capacity above critical power (W′) ÷ (P − CP) [4, pp. 291–292]. Above CP, W′ is spent at rate P − CP; the animated tank shows it emptying.
At this level you should: Derive critical power (CP) and work capacity above critical power (W′) from trials and check the fit. (Advanced)
From the three-trial sample, the module’s curve uses CP 240 W and W′ 18 kJ, giving 300 s at 300 W. Monark power, the American College of Sports Medicine (ACSM) submaximal oxygen uptake (V̇O₂) and standard temperature and pressure, dry (STPD) conversions are in the calculators.
At this level you should: Appraise reliability and reporting. (Postgraduate)
Coefficient of variation (CV) % is the simplest reliability statistic (Freivalds p. 363; 16.11). State calibration, environment and protocol so tests can be repeated (16.2).
Evidence stated in the extracted sources · Interpretation practical reading of that evidence · Example illustrative scenario.
P = work capacity above critical power (W′) × (1/t) + CP. W′ and CP from trials 1 and 3 (as in the extracted sample); trial 2 is then compared with the model prediction.
ConceptCritical power and the finite work capacity above it are found from two or more exhaustive constant-power trials.
Why it mattersThey define the boundary between sustainable and unsustainable intensities.
Reading the figureType or step the values on the left; the results on the right update at once. Every result comes from the formula printed beneath the results, with units shown under each number.
ControlsWhat each control means, and what responds when you move it (worked out from this model across the control's full range):
What to take awayPlotting power against 1 ÷ time gives a straight line: the slope is the work capacity and the intercept is critical power.
Assumptions and limitsThe source sample uses trials 1 and 3; trial 2 checks the fit.
Play a constant-power effort: W′ drains at P − CP until exhaustion. Below CP there is no depletion in this model.
ConceptAbove critical power, the finite work capacity is spent at a rate equal to the power above critical power; exhaustion occurs when it reaches zero.
Why it mattersIt is the basis for pacing efforts and designing intervals.
Reading the figure The tank is the remaining work capacity; the bars compare effort power with critical power. Play runs the effort.
ControlsWhat each control means, and what responds when you move it (worked out from this model across the control's full range):
What to take awayWith 18 kJ and a critical power of 240 W, 300 W lasts 300 s in the model.
Assumptions and limitsRecovery of the capacity below critical power is not modelled because the source gives no rate.
The two-parameter model P(t) = work capacity above critical power (W′)/t + critical power (CP) using W′ and CP from trials 1 and 3 of the calculator inputs below (defaults: 340 W/180 s and 265 W/720 s).
ConceptThe power–duration curve drawn from critical power and work capacity.
Why it mattersIt predicts the time a given power can be held.
Reading the figureThe horizontal axis is duration (s) and the vertical axis is power (W). The line is the stated equation evaluated across the axis range; the dot and dashed line mark the probe, and the readout gives the value at the probe.
ControlsWhat each control means, and what responds when you move it (worked out from this model across the control's full range):
What to take awayThe curve approaches critical power as duration increases.
Assumptions and limitsTwo-parameter model.
V̇O₂ (mL/min) = 10.8 × P + 7.0 × m + 300; PMonark = mapplied × 9.80665 × 6.0 × N ÷ 60; CV (%) = s ÷ x̄ × 100.
ConceptThree laboratory calculations: predicted oxygen uptake from power, power on a friction-braked ergometer, and the coefficient of variation.
Why it mattersThey are routine in test set-up and reporting.
Reading the figureType or step the values on the left; the results on the right update at once. Every result comes from the formula printed beneath the results, with units shown under each number.
ControlsWhat each control means, and what responds when you move it (worked out from this model across the control's full range):
What to take awayThe coefficient of variation is standard deviation ÷ mean × 100.
Assumptions and limitsPrediction equations give estimates, not measurements.
Questions are drawn from the extracted module content above.
Text, values and source attributions are shown as extracted from the project's source library for this module.
Subcategory register: evidence status and primary identifiers.
| ID | Subcategory | Status | Source coverage and identifiers |
|---|---|---|---|
| 16.1 | Pre-test screening and contraindications | EVIDENCE FOUND | karim khan.pdf p. 150, 154, 159, Table 45.8, Table 45.9; The\_Sports\_Medicine\_Physician p. 128–129; Sport injury 2nd Ed (Fu Part 1\) p. 159 |
| 16.2 | Equipment calibration and environmental control | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 101, 166, 174, 212, 220–221; karim khan.pdf p. 158; lactate-threshold-training (Janssen) p. 165–166 |
| 16.3 | Incremental cycling tests | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 105, 212, 286, 289–291; cycling.pdf p. 56–57; cycling-physiology-training-science-guide.pdf p. 30, 145 |
| 16.4 | Maximal oxygen uptake (VO₂max) and verification protocols | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 195–196, 290; A Guide to Sports and Injury Management p. 1; cycling.pdf p. 57; Sports Rehabilitation and Injury Prevention p. 115 |
| 16.5 | Ventilatory and lactate threshold protocols | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 283–289, 297, 307; Sports Specific rehab (Donatelli) p. 50, 52, 69–70; cycling-physiology-training-science-guide.pdf p. 22–23 |
| 16.6 | Critical power testing and protocol design | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 291–292, 307–308; cycling-physiology-training-science-guide.pdf p. 22–24, 138–141; Master Resource Module 16/20 |
| 16.7 | Submaximal testing and prediction methods | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 212, 254; Sport injury 2nd Ed (Fu Part 1\) p. 38; Sports Specific rehab (Donatelli) p. 80; lactate-threshold-training (Janssen) p. 170 |
| 16.8 | Spirometry and cardiorespiratory measurements where relevant | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 101–105, 174–180; Textbook of Sports Medicine p. 60, 127; cycling.pdf p. 48, 84 |
| 16.9 | Heart-rate, power and perceived-exertion monitoring | EVIDENCE FOUND | KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 212, 258–262, 270, 296, 308–310; lactate-threshold-training (Janssen) p. 168–169; cyclingfitness-autumn2013.pdf p. 146 |
| 16.10 | Test termination and adverse-event procedures | EVIDENCE FOUND | karim khan.pdf p. 155–156, Table 45.9; Textbook of Sports Medicine p. 124; KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 212 |
| 16.11 | Reliability, validity and reporting standards | EVIDENCE FOUND | Biomechanics of Upper Limbs (Freivalds) p. 363–368; Sports Biomechanics (Blazevich) p. 108–109; KINANTHROPOMETRY AND EXERCISE (Eston & Reilly) p. 21, 382; Sports Rehabilitation p. 31 |
Numbered in order of first citation in this module. Each entry shows only the bibliographic details the project's source artefacts record; entries marked Unverified have not been checked against the source itself.
Listed in this module's extracted reference list but not cited directly in the academic content above. The note after each entry records where the extraction found it.
These items appeared in the module's reference list but are not bibliographic entries; they are reproduced unchanged.